{"product_id":"seco-larm-e-941da-600q-double-door-electromagnetic-lock","title":"SECO-LARM E-941DA-600Q Double-door Electromagnetic Lock","description":"\u003ch3\u003eSECO-LARM E-941DA-600Q Double-door Electromagnetic Lock\u003c\/h3\u003e\n\u003cp\u003eThe E-941Dx series of electromagnetic locks is the ideal way to secure a door against unauthorized entry. When power is applied to the electromagnetic lock, it creates an extremely strong magnetic field. The electromagnet is strongly attracted to the steel armature plate which is mounted on the secured door. Once the electromagnet is deactivated, the secured door will function normally without any residual magnetism.\u003c\/p\u003e\n\u003ch5\u003eFeature:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e600-lb (272kg) Holding force per door\u003c\/li\u003e\n\u003cli\u003eNo residual magnetism\u003c\/li\u003e\n\u003cli\u003eMOV Surge protection\u003c\/li\u003e\n\u003cli\u003eAnodized aluminum housing (US 28)\u003c\/li\u003e\n\u003cli\u003eAdjustable mounting bracket\u003c\/li\u003e\n\u003cli\u003eComplete mounting hardware for typical installations\u003c\/li\u003e\n\u003cli\u003eAdditional brackets available for easy mounting or atypical situations\u003c\/li\u003e\n\u003cli\u003eDetachable faceplate for easy access to wiring\u003c\/li\u003e\n\u003cli\u003e12\/24VDC Selectable\u003c\/li\u003e\n\u003cli\u003eMultiple UL listings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eUL294 Access Control System Units – USA\u003c\/li\u003e\n\u003cli\u003eUL10C Positive Pressure Fire Test – USA\u003c\/li\u003e\n\u003cli\u003eUL10B Fire Test of Door Assemblies – USA\u003c\/li\u003e\n\u003cli\u003eULC-S104 Fire Test of Door Assemblies – Canada\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eLifetime limited warranty*\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*Warranty applies in the USA and Canada only. Contact SECO­LARM for details.\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eSpecifications:\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHolding force\u003c\/td\u003e\n\u003ctd\u003e600-lb (272kg) per door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e12 \/24 VDC (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent draw\u003c\/td\u003e\n\u003ctd\u003e500mA@12VDC per door (1A total) 270mA@24VDC per door (540mA total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e32º~120º F (0º~49º C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnet dimensions\u003c\/td\u003e\n\u003ctd\u003e19-11\/16″ x 1-5\/8″ x 1-1\/16″ (500x40x26 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmature dimensions\u003c\/td\u003e\n\u003ctd\u003e7-1\/4″x1-1\/2″x1\/2″(185x38x12 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9-lb (4kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDestructive attack\u003c\/td\u003e\n\u003ctd\u003eLevel I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine security\u003c\/td\u003e\n\u003ctd\u003eLevel I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby power\u003c\/td\u003e\n\u003ctd\u003eLevel I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndurance\u003c\/td\u003e\n\u003ctd\u003eLevel IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eTroubleshooting:\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoors lock, but can easily be forced open\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMake sure the electromagnet and armature plates are properly aligned.\u003c\/li\u003e\n\u003cli\u003eMake sure the contact surfaces of the electromagnet and armature plates are clean and free from rust.\u003c\/li\u003e\n\u003cli\u003eCheck the power leads with a meter, and make sure 12VDC or 24VDC is present.\u003c\/li\u003e\n\u003cli\u003eMake sure the rubber washer is installed and free from damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay in door releasing\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe electromagnet is fitted with a metal oxide varistor to prevent interference, so do not install a second diode.\u003c\/li\u003e\n\u003cli\u003eEnsure that the control device is connected between the power source and the positive terminal of the lock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownload:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0951\/0596\/files\/PI_E-941DA-xxxx_221117.pdf?v=1689368483\" target=\"_blank\" title=\"Product Information Sheet\" rel=\"noopener noreferrer\"\u003eProduct Information Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0951\/0596\/files\/MI_E-941Dx-xxxQ_220513.pdf?v=1689368484\" target=\"_blank\" title=\"Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0951\/0596\/files\/E-941DA-600_Template_8e973a1e-88eb-420f-b194-88f287b4ba05.pdf?v=1689368483\" target=\"_blank\" title=\"Mounting Template\" rel=\"noopener noreferrer\"\u003eMounting Template\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SECO-LARM","offers":[{"title":"Default Title","offer_id":50965975105843,"sku":"SECO-E-941DA-600Q","price":190.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0745\/3445\/3555\/files\/SECO-E-941DA-600Q__1.jpg?v=1737215581","url":"https:\/\/ecs-hardware.com\/products\/seco-larm-e-941da-600q-double-door-electromagnetic-lock","provider":"Locksmith Keyless TEST STORE","version":"1.0","type":"link"}